Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Language
Document Type
Year range
1.
Insights into Imaging ; 13(1), 2022.
Article in English | ProQuest Central | ID: covidwho-1837326

ABSTRACT

BackgroundDuring the current severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) pandemic, computed tomography (CT) has become widely used in patients with suspected or known coronavirus disease 2019 (COVID-19). This prospective observational study in 28 invasively ventilated and 18 non-invasively ventilated patients with confirmed SARS-CoV-2 contamination aims at investigating SARS-CoV-2 contamination of CT scanner surfaces and its infectiousness.MethodsSwab sampling of the CT table and gantry before and after CT examinations was performed. Additionally, the CT ventilation system air grid was wiped off after each examination. Real-time reverse-transcription polymerase chain reaction (RT-PCR) for SARS-CoV-2 RNA (ribonucleic acid) and viral cell culture were performed in the virology core lab.ResultsAfter examination of non-invasively ventilated or non-ventilated patients, SARS-CoV-2 RNA was found in 11.1% (4/36) on patient near surfaces (CT table and gantry) and in 16.7% (3/18) on the CT air grid respectively after examination of invasively ventilated patients in 5.4% (3/56) on CT table and gantry and 7.1% (2/28) on the CT air grid. Surface contamination was more common in non-invasively ventilated or non-ventilated patients with a high viral load who were actively coughing. RT-PCR cycle threshold (Ct) was high (35.96–39.31) in all positive samples and no positive viral cell culture was found.ConclusionOur study suggests that CT scanner surface contamination with SARS-CoV-2 is considerable and more common after examination of non-invasively ventilated or non-ventilated patients compared to invasively ventilated patients. However, no viral cell culture positivity was found, hence the infectious potential seems low.

2.
EClinicalMedicine ; 28: 100579, 2020 Nov.
Article in English | MEDLINE | ID: covidwho-845228

ABSTRACT

BACKGROUND: In face of the Coronavirus Disease (COVID)-19 pandemic, best practice for mechanical ventilation in COVID-19 associated Acute Respiratory Distress Syndrome (ARDS) is intensely debated. Specifically, the rationale for high positive end-expiratory pressure (PEEP) and prone positioning in early COVID-19 ARDS has been questioned. METHODS: The first 23 consecutive patients with COVID-19 associated respiratory failure transferred to a single ICU were assessed. Eight were excluded: five were not invasively ventilated and three received veno-venous ECMO support. The remaining 15 were assessed over the first 15 days of mechanical ventilation. Best PEEP was defined by maximal oxygenation and was determined by structured decremental PEEP trials comprising the monitoring of oxygenation, airway pressures and trans-pulmonary pressures. In nine patients the impact of prone positioning on oxygenation was investigated. Additionally, the effects of high PEEP and prone positioning on pulmonary opacities in serial chest x-rays were determined by applying a semiquantitative scoring-system. This investigation is part of the prospective observational PA-COVID-19 study. FINDINGS: Patients responded to initiation of invasive high PEEP ventilation with markedly improved oxygenation, which was accompanied by reduced pulmonary opacities within 6 h of mechanical ventilation. Decremental PEEP trials confirmed the need for high PEEP (17.9 (SD ± 3.9) mbar) for optimal oxygenation, while driving pressures remained low. Prone positioning substantially increased oxygenation (p<0.01). INTERPRETATION: In early COVID-19 ARDS, substantial PEEP values were required for optimizing oxygenation. Pulmonary opacities resolved during mechanical ventilation with high PEEP suggesting recruitment of lung volume. FUNDING: German Research Foundation, German Federal Ministry of Education and Research.

SELECTION OF CITATIONS
SEARCH DETAIL